Lab Pua Twin Header series Strong Carbon Kit 5 and 1 Micron set
$247.87 incl. GST
Lab Pua Twin Header series Strong Carbon Kit 5 and 1 Micron set
Lab Pua Twin Header series Strong Carbon Kit 5 and 1 Micron set
LPA-CB5-17+LPA-CS5-17
SPECIFICATIONS
Service Flow Rate |
2.1GPM (7.94L/min) |
Rated Capacity |
21,000 Gallon (79,484L) |
Operation Temperature |
4~38℃ (39~100℉) |
Pressure Requirements |
10~100 psi (0.7~6.9bar) |
Inlet / Outlet Connection |
3/8″ |
Electrical Connection |
None required |
Dimension |
Overall : 3.7″*18.8″ Cartridge : Ø3.3″*17.4″ |
Weight |
1.0kg |
Claim |
Chlorine, Taste and Odor, Particulate Class 1 (0.5~1.0um) |
FEATURES · BENEFITS
• HNN’ s carbon block is made by high quality and quantity gac.
(Therefore, water quality is more stable and Capacity is bigger than competitor’s products)
• 5micron pore size CTO Block
• Extrusion carbon production method provides stable quality and
• Pre-shield Technology can prevent early clogging and keep the lifespan.
• Replacement method is easy quick-change.
LPA-CS5-17 SPECIFICATIONS
Service Flow Rate |
2.1GPM (7.94L/min) |
Rated Capacity |
21,000 Gallon (79,484L) |
Operation Temperature |
4~38℃ (39~100℉) |
Pressure Requirements |
10~100 psi (0.7~6.9bar) |
Inlet / Outlet Connection |
3/8″ |
Electrical Connection |
None required |
Dimension |
Overall : 3.7″*18.8″ Cartridge : Ø3.3″*17.4″ |
Weight |
1.1kg |
Claim |
Chlorine, Taste and Odor, Particulate, Scale Inhibitor |
FEATURES · BENEFITS
• Phosphate can prevent to make scale in boiler or heater (phosphate)
• 5micron pore size CTO Block
• Extrusion carbon production method provides stable quality and
• Pre-shield Technology can prevent early clogging and keep the lifespan.
• Replacement method is easy quick-change.
Installation Instruction
1. Turn off main tap water.
2. Rotate the old cartridge counter clockwise ¼ turn and pull it out.
3. Insert the new cartridge into the filter head and rotate clockwise 1/4 turn.
4. Please the cartridge to the vertical position.
5. Turn on the main tap water and check for leaks. If leaks occurs, repeat step 1, 2, 3,4. If leaks persist, discontinue use and call your supporting dealer.
6. Flush filter for 10minutes before use.
Operation Tips
1. For cold water only.
2. Filter should be replaced by each required replacement date.
3. The testing was performed under standard laboratory conditions, actual performance may very.
4. Check for compliance with the state and local laws and regulations.
5. System must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines.
6. Be sure to use the pressure reducing valve, If the water pressure exceeds 4bar.
LAB PUA Carbon Block Filter(CB5&CS5 Series)
LAB PUA MODEL SPEC CHART
LAB PUA TWIN-SERIES HEAD
• Model : LPA238QC
• Dimension : 222.9 X 119.5 X 72.5 (WXHXD)
• MOQ : 12pcs/box
• Features mounting bracket and 3/8″ fittings
• Quick-Change Type Head(Manifold)
• Includes built-in water shut-off valve (Auto Shut-Off Valve)
Product Type | Twin Head only, Twin Head + 10" Cartridges LPA-CS5-10 + LPA-MP1S-10 |
---|