Lab Pua Twin Header series Sediment with 0.1 Micron Ultra Fine &Scale Filter KIT
$208.00 incl. GST
Lab Pua Twin Header series Sediment with 0.1 Micron Ultra Fine &Scale Filter KIT
Lab Pua Twin Header series Sediment with 0.1 Micron Ultra Fine &Scale Filter KIT
LPA-SD5-17+ LPA-MP1S-17
LPA SD5 17
SPECIFICATIONS
Service Flow Rate |
2.5GPM (7.94L/min) |
Rated Capacity |
6 Months |
Operation Temperature |
4~38℃ (39~100℉) |
Pressure Requirements |
10~100 psi (0.7~6.9bar) |
Inlet / Outlet Connection |
3/8″ |
Electrical Connection |
None required |
Dimension |
Overall : 3.7″*18.8″ Cartridge : Ø3.3″*17.4″ |
Weight |
0.7kg |
Claim |
Particle, Dust and Sand, etc |
FEATURES · BENEFITS
• Pretreatment filtration (PP, Melt Blown Type)
• Can remove up to 5micron particles through mechanical method.
• Replacement method is very simple, quick and clean.
LPA-MP1S-17 SPECIFICATIONS
Service Flow Rate |
2.1GPM (7.94L/min) |
Rated Capacity |
13,210 Gallon (50,000L) |
Operation Temperature |
4~38℃ (39~100℉) |
Pressure Requirements |
10~100 psi (0.7~6.9bar) |
Inlet / Outlet Connection |
3/8″ |
Electrical Connection |
None required |
Dimension |
Overall : 3.7″*18.8″ Cartridge : Ø3.3″*17.4″ |
Weight |
0.95kg |
Claim |
Chlorine, Taste and Odor, Particulate, Bacteria & Cyst, Scale Inhibitor |
FEATURES · BENEFITS
• Composite filter is made with carbon and hollow Fiber
• 0.1um pore size can remove bacteria and cyst
• LPA-MP-1-17 has one more carbon block . The carbon block can improve water taste and odor
• Replacement method is easy quick-change.
• Phosphate can prevent to make scale in boiler or heater (phosphate)
Installation Instruction
1. Turn off main tap water.
2. Rotate the old cartridge counter clockwise ¼ turn and pull it out.
3. Insert the new cartridge into the filter head and rotate clockwise 1/4 turn.
4. Please the cartridge to the vertical position.
5. Turn on the main tap water and check for leaks. If leaks occurs, repeat step 1, 2, 3,4. If leaks persist, discontinue use and call your supporting dealer.
6. Flush filter for 10minutes before use.
Operation Tips
1. For cold water only.
2. Filter should be replaced by each required replacement date.
3. The testing was performed under standard laboratory conditions, actual performance may very.
4. Check for compliance with the state and local laws and regulations.
5. System must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines.
6. Be sure to use the pressure reducing valve, If the water pressure exceeds 4bar.
Product Type | Twin Head only, Twin Head + 10" Cartridges LPA-CS5-10 + LPA-MP1S-10 |
---|